Error in model: BESMod.Systems.Hydraulical.Generation.Tests.HeatPump
Check of BESMod.Systems.Hydraulical.Generation.Tests.HeatPump:
Warning: Failed to evaluate and check the size declaration of systemParameters.QBui_flow_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: Failed to evaluate and check the size declaration of systemParameters.THydSup_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.nSet is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TConInMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TEvaOutMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowEvaMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowConMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Error: The following parameter doesn't have any value:
generation.dpDemOld_design
The model has the same number of unknowns and equations: 925
The model could not be deduced to be symbolically well-posed.
The model has
913+generation.heatPump.con.vol.dynBal.nPorts+2*generation.heatPump.eva.vol.dynBal.nPorts +generation.pump.vol.dynBal.nPorts+generation.multiSum.nu+vol[1].dynBal.nPorts
scalar unknowns and
878+(if generation.bou_sinkAir.use_Xi_in then 2 else (if generation.bou_sinkAir.use_X_in then 1 else 3))+(if not generation.bou_sinkAir.use_p_in then 1 else 0)+(if not generation.bou_sinkAir.use_h_in then 1 else 0)+(if generation.bouEva.use_Xi_in then 2 else (if generation.bouEva.use_X_in then 1 else 3))+(if generation.bouPum.use_Xi_in then 1 else (if generation.bouPum.use_X_in then 0 else 1))+(if not generation.bouPum.use_p_in then 1 else 0)+(if not generation.bouPum.use_T_in then 1 else 0)+(if weaDat.pAtmSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDewPoiSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDryBulSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TBlaSkySou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.relHumSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.opaSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.ceiHeiSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.totSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winSpeSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winDirSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HInfHorSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HDifHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HGloHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HGloHor_HDifHor then 2 else 1)+(if not generation.heatPump.con.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.heatPump.con.vol.dynBal.nPorts+(if not generation.heatPump.eva.vol.dynBal.use_mWat_flow then 1 else 0)+5* generation.heatPump.eva.vol.dynBal.nPorts+(if not generation.pump.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.pump.vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
925
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Generation.Tests.ElectricalHeater
Check of BESMod.Systems.Hydraulical.Generation.Tests.ElectricalHeater:
Error: The following parameter doesn't have any value:
generation.dpDemOld_design
The model has the same number of unknowns and equations: 543
The model could not be deduced to be symbolically well-posed.
The model has
537+generation.hea.vol.dynBal.nPorts+generation.pump.vol.dynBal.nPorts+ vol[1].dynBal.nPorts
scalar unknowns and
513+(if generation.bou1.use_Xi_in then 1 else (if generation.bou1.use_X_in then 0 else 1))+(if not generation.bou1.use_p_in then 1 else 0)+2*generation.bou1.nPorts +(if not generation.bou1.use_T_in then 1 else 0)+(if weaDat.pAtmSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDewPoiSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDryBulSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TBlaSkySou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.relHumSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.opaSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.ceiHeiSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.totSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winSpeSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winDirSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HInfHorSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HDifHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HGloHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HGloHor_HDifHor then 2 else 1)+(if not generation.hea.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.hea.vol.dynBal.nPorts+(if not generation.pump.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.pump.vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
543
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Distribution.Tests.TestOnlyDHW
Check of BESMod.Systems.Hydraulical.Distribution.Tests.TestOnlyDHW:
Error: The following parameters don't have any value:
distribution.mDemOld_flow_design
distribution.mSupOld_flow_design
The model has the same number of unknowns and equations: 401
The model could not be deduced to be symbolically well-posed.
The model has
395+fanTra[1].vol.dynBal.nPorts+fanDHW.vol.dynBal.nPorts+fanGen[1].vol.dynBal.nPorts
scalar unknowns and
371+(if bouDHW.use_Xi_in then 1 else (if bouDHW.use_X_in then 0 else 1))+(if not bouDHW.use_p_in then 1 else 0)+(if not bouDHW.use_T_in then 1 else 0)+( if bouTra[1].use_Xi_in then 1 else (if bouTra[1].use_X_in then 0 else 1))+(if not bouTra[1].use_p_in then 1 else 0)+(if not bouTra[1].use_T_in then 1 else 0)+(if bouTra1[1].use_Xi_in then 1 else (if bouTra1[1].use_X_in then 0 else 1))+(if not bouTra1[1].use_p_in then 1 else 0)+(if not bouTra1[1].use_T_in then 1 else 0)+(if not fanTra[1].vol.dynBal.use_mWat_flow then 1 else 0)+3*fanTra[1].vol.dynBal.nPorts+(if not fanDHW.vol.dynBal.use_mWat_flow then 1 else 0)+3*fanDHW.vol.dynBal.nPorts+(if not fanGen[1].vol.dynBal.use_mWat_flow then 1 else 0)+3*fanGen[1].vol.dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
401
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Generation.Tests.HeatPumpAndGasBoilerParallel
Check of BESMod.Systems.Hydraulical.Generation.Tests.HeatPumpAndGasBoilerParallel:
Warning: Failed to evaluate and check the size declaration of systemParameters.QBui_flow_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: Failed to evaluate and check the size declaration of systemParameters.THydSup_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: Non-literal value.
In nominal attribute for generation.boi.pressureDrop.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class generation.boi.pressureDrop.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.nSet is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TConInMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TEvaOutMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowEvaMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowConMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Error: The following parameter doesn't have any value:
generation.dpDemOld_design
The model has the same number of unknowns and equations: 1219
The model could not be deduced to be symbolically well-posed.
The model has
1202+generation.heatPump.con.vol.dynBal.nPorts+2*generation.heatPump.eva.vol.dynBal.nPorts +generation.pump.vol.dynBal.nPorts+generation.multiSum.nu+generation.boi.vol.dynBal.nPorts +generation.thrWayVal.threWayValFlow.vol.dynBal.nPorts+vol[1].dynBal.nPorts
scalar unknowns and
1155+(if generation.bou_sinkAir.use_Xi_in then 2 else (if generation.bou_sinkAir.use_X_in then 1 else 3))+(if not generation.bou_sinkAir.use_p_in then 1 else 0)+(if not generation.bou_sinkAir.use_h_in then 1 else 0)+(if generation.bouEva.use_Xi_in then 2 else (if generation.bouEva.use_X_in then 1 else 3))+(if generation.bouPum.use_Xi_in then 1 else (if generation.bouPum.use_X_in then 0 else 1))+(if not generation.bouPum.use_p_in then 1 else 0)+(if not generation.bouPum.use_T_in then 1 else 0)+(if weaDat.pAtmSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDewPoiSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDryBulSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TBlaSkySou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.relHumSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.opaSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.ceiHeiSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.totSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winSpeSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winDirSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HInfHorSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HDifHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HGloHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HGloHor_HDifHor then 2 else 1)+(if not generation.heatPump.con.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.heatPump.con.vol.dynBal.nPorts+(if not generation.heatPump.eva.vol.dynBal.use_mWat_flow then 1 else 0)+5* generation.heatPump.eva.vol.dynBal.nPorts+(if not generation.pump.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.pump.vol.dynBal.nPorts+(if not generation.boi.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.boi.vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts+(if not generation.thrWayVal.threWayValFlow.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.thrWayVal.threWayValFlow.vol.dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
1219
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Transfer.Tests.TestPressureBasedSystemWithReliefValve
Check of BESMod.Systems.Hydraulical.Transfer.Tests.TestPressureBasedSystemWithReliefValve:
Error: The following parameter doesn't have any value:
transfer.dpSupOld_design
Warning: The following parameters don't have any value, only a start value:
transfer.TTraOld_design(start = {288.15})
The model has the same number of unknowns and equations: 674
The model could not be deduced to be symbolically well-posed.
The model has
637+2*transfer.parRad.nEle+transfer.rad[1].vol[1].dynBal.nPorts+transfer.rad[1].vol[2].dynBal.nPorts +transfer.rad[1].vol[3].dynBal.nPorts+transfer.rad[1].vol[4].dynBal.nPorts+ transfer.rad[1].vol[5].dynBal.nPorts+transfer.rad[1].sumCon.nin+ transfer.rad[1].sumRad.nin+transfer.vol.dynBal.nPorts+transfer.pump.vol.dynBal.nPorts +vol[1].dynBal.nPorts
scalar unknowns and
602+(if bou1[1].use_Xi_in then 1 else (if bou1[1].use_X_in then 0 else 1))+(if not bou1[1].use_p_in then 1 else 0)+(if not bou1[1].use_T_in then 1 else 0)+ (if not transfer.rad[1].vol[1].dynBal.use_mWat_flow then 1 else 0)+3* transfer.rad[1].vol[1].dynBal.nPorts+(if not transfer.rad[1].vol[2].dynBal.use_mWat_flow then 1 else 0)+3*transfer.rad[1].vol[2].dynBal.nPorts+(if not transfer.rad[1].vol[3].dynBal.use_mWat_flow then 1 else 0)+3*transfer.rad[1].vol[3].dynBal.nPorts +(if not transfer.rad[1].vol[4].dynBal.use_mWat_flow then 1 else 0)+3* transfer.rad[1].vol[4].dynBal.nPorts+(if not transfer.rad[1].vol[5].dynBal.use_mWat_flow then 1 else 0)+3*transfer.rad[1].vol[5].dynBal.nPorts+(if not transfer.vol.dynBal.use_mWat_flow then 1 else 0)+3*transfer.vol.dynBal.nPorts+ (if not transfer.pump.vol.dynBal.use_mWat_flow then 1 else 0)+3* transfer.pump.vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts+2*transfer.parRad.nEle
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
674
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Distribution.Tests.TestIndirectLoading
Check of BESMod.Systems.Hydraulical.Distribution.Tests.TestIndirectLoading:
Warning: Failed to evaluate and check the size declaration of systemParameters.QBui_flow_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: Non-literal value.
In nominal attribute for distribution.stoBuf.heatingCoil1.pipe[1].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoBuf.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoBuf.heatingCoil1.pipe[2].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoBuf.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoBuf.heatingCoil1.pipe[3].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoBuf.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoBuf.heatingCoil1.pipe[4].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoBuf.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[1].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[2].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[3].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[4].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Error: The following parameters don't have any value:
distribution.mDemOld_flow_design
distribution.mSupOld_flow_design
The model has the same number of unknowns and equations: 3192
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Distribution.Tests.TestCombiStorage
Check of BESMod.Systems.Hydraulical.Distribution.Tests.TestCombiStorage:
Warning: Incompatible sizes for variable and its definition equation;
distribution.TSupOld_design = distribution.TDemOld_design.+distribution.dTLoss_nominal.+distribution.dTTraOld_design
They have for dimension 1 the sizes 2 and 1.
Errors detected in variable declarations.
Check of class aborted.
Warning: WARNINGS have been issued.
Error in model: BESMod.Systems.Hydraulical.Generation.Tests.GasBoiler
Check of BESMod.Systems.Hydraulical.Generation.Tests.GasBoiler:
Warning: Non-literal value.
In nominal attribute for generation.boi.pressureDrop.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class generation.boi.pressureDrop.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Error: The following parameter doesn't have any value:
generation.dpDemOld_design
The model has the same number of unknowns and equations: 584
The model could not be deduced to be symbolically well-posed.
The model has
578+generation.boi.vol.dynBal.nPorts+generation.pump.vol.dynBal.nPorts+ vol[1].dynBal.nPorts
scalar unknowns and
554+(if generation.bou1.use_Xi_in then 1 else (if generation.bou1.use_X_in then 0 else 1))+(if not generation.bou1.use_p_in then 1 else 0)+2*generation.bou1.nPorts +(if not generation.bou1.use_T_in then 1 else 0)+(if weaDat.pAtmSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDewPoiSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDryBulSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TBlaSkySou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.relHumSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.opaSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.ceiHeiSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.totSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winSpeSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winDirSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HInfHorSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HDifHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HGloHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HGloHor_HDifHor then 2 else 1)+(if not generation.boi.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.boi.vol.dynBal.nPorts+(if not generation.pump.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.pump.vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
584
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Transfer.Tests.TestPressureBasedSystem
Check of BESMod.Systems.Hydraulical.Transfer.Tests.TestPressureBasedSystem:
Error: The following parameter doesn't have any value:
transfer.dpSupOld_design
Warning: The following parameters don't have any value, only a start value:
transfer.TTraOld_design(start = {288.15})
The model has the same number of unknowns and equations: 633
The model could not be deduced to be symbolically well-posed.
The model has
596+2*transfer.parRad.nEle+transfer.rad[1].vol[1].dynBal.nPorts+transfer.rad[1].vol[2].dynBal.nPorts +transfer.rad[1].vol[3].dynBal.nPorts+transfer.rad[1].vol[4].dynBal.nPorts+ transfer.rad[1].vol[5].dynBal.nPorts+transfer.rad[1].sumCon.nin+ transfer.rad[1].sumRad.nin+transfer.vol.dynBal.nPorts+transfer.pump.vol.dynBal.nPorts +vol[1].dynBal.nPorts
scalar unknowns and
561+(if bou1[1].use_Xi_in then 1 else (if bou1[1].use_X_in then 0 else 1))+(if not bou1[1].use_p_in then 1 else 0)+(if not bou1[1].use_T_in then 1 else 0)+ (if not transfer.rad[1].vol[1].dynBal.use_mWat_flow then 1 else 0)+3* transfer.rad[1].vol[1].dynBal.nPorts+(if not transfer.rad[1].vol[2].dynBal.use_mWat_flow then 1 else 0)+3*transfer.rad[1].vol[2].dynBal.nPorts+(if not transfer.rad[1].vol[3].dynBal.use_mWat_flow then 1 else 0)+3*transfer.rad[1].vol[3].dynBal.nPorts +(if not transfer.rad[1].vol[4].dynBal.use_mWat_flow then 1 else 0)+3* transfer.rad[1].vol[4].dynBal.nPorts+(if not transfer.rad[1].vol[5].dynBal.use_mWat_flow then 1 else 0)+3*transfer.rad[1].vol[5].dynBal.nPorts+(if not transfer.vol.dynBal.use_mWat_flow then 1 else 0)+3*transfer.vol.dynBal.nPorts+ (if not transfer.pump.vol.dynBal.use_mWat_flow then 1 else 0)+3* transfer.pump.vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts+2*transfer.parRad.nEle
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
633
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Distribution.Tests.TestOnlyBuilding
Check of BESMod.Systems.Hydraulical.Distribution.Tests.TestOnlyBuilding:
Error: The following parameters don't have any value:
distribution.mDemOld_flow_design
distribution.mSupOld_flow_design
The model has the same number of unknowns and equations: 404
The model could not be deduced to be symbolically well-posed.
The model has
398+fanTra[1].vol.dynBal.nPorts+fanDHW.vol.dynBal.nPorts+fanGen[1].vol.dynBal.nPorts
scalar unknowns and
374+(if bouDHW.use_Xi_in then 1 else (if bouDHW.use_X_in then 0 else 1))+(if not bouDHW.use_p_in then 1 else 0)+(if not bouDHW.use_T_in then 1 else 0)+( if bouTra[1].use_Xi_in then 1 else (if bouTra[1].use_X_in then 0 else 1))+(if not bouTra[1].use_p_in then 1 else 0)+(if not bouTra[1].use_T_in then 1 else 0)+(if bouTra1[1].use_Xi_in then 1 else (if bouTra1[1].use_X_in then 0 else 1))+(if not bouTra1[1].use_p_in then 1 else 0)+(if not bouTra1[1].use_T_in then 1 else 0)+(if not fanTra[1].vol.dynBal.use_mWat_flow then 1 else 0)+3*fanTra[1].vol.dynBal.nPorts+(if not fanDHW.vol.dynBal.use_mWat_flow then 1 else 0)+3*fanDHW.vol.dynBal.nPorts+(if not fanGen[1].vol.dynBal.use_mWat_flow then 1 else 0)+3*fanGen[1].vol.dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
404
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Distribution.Tests.TestDirectLoading
Check of BESMod.Systems.Hydraulical.Distribution.Tests.TestDirectLoading:
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[1].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[2].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[3].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[4].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Error: The following parameters don't have any value:
distribution.mDemOld_flow_design
distribution.mSupOld_flow_design
The model has the same number of unknowns and equations: 2440
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Distribution.CombiStorage
Check of BESMod.Systems.Hydraulical.Distribution.CombiStorage:
Component type specifier BaseProperties is a partial type
It must be redeclared before being used.
File: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 78
Component context: bufSto.layer.dynBal.medium
Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium
Component type specifier BaseProperties is a partial type
It must be redeclared before being used.
File: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 78
Component context: bufSto.heatingCoil1.pipe.vol_b.dynBal.medium
Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium
Component type specifier BaseProperties is a partial type
It must be redeclared before being used.
File: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 78
Component context: bufSto.heatingCoil1.pipe.vol_a.dynBal.medium
Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium
Component type specifier BaseProperties is a partial type
It must be redeclared before being used.
File: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 78
Component context: bufSto.heatingCoil2.pipe.vol_b.dynBal.medium
Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium
Component type specifier BaseProperties is a partial type
It must be redeclared before being used.
File: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 78
Component context: bufSto.heatingCoil2.pipe.vol_a.dynBal.medium
Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium
Check is assuming: Q_flow_nominal = fill(1e-15, 1)
Check is assuming: mDHW_flow_nominal = 1e-15
Check is assuming: mSup_flow_nominal = fill(1e-15, 2)
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].res.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.res.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].res.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.res.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class bufSto.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].del.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.del.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].del.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.del.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].heaLos_a.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_a.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].heaLos_a.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_a.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].heaLos_b.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_b.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].heaLos_b.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_b.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].senMasFlo.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.senMasFlo.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[1].senMasFlo.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.senMasFlo.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].res.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.res.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].res.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.res.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class bufSto.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].del.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.del.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].del.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.del.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].heaLos_a.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_a.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].heaLos_a.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_a.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].heaLos_b.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_b.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].heaLos_b.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_b.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].senMasFlo.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.senMasFlo.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[2].senMasFlo.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.senMasFlo.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].res.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.res.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].res.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.res.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class bufSto.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].del.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.del.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].del.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.del.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].heaLos_a.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_a.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].heaLos_a.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_a.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].heaLos_b.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_b.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].heaLos_b.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_b.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].senMasFlo.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.senMasFlo.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[3].senMasFlo.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.senMasFlo.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].res.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.res.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].res.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.res.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class bufSto.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].del.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.del.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].del.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.del.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].heaLos_a.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_a.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].heaLos_a.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_a.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].heaLos_b.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_b.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].heaLos_b.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.heaLos_b.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].senMasFlo.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.senMasFlo.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil1.pipe[4].senMasFlo.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil1.pipe.senMasFlo.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].res.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.res.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].res.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.res.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class bufSto.heatingCoil2.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].del.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.del.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].del.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.del.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].heaLos_a.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.heaLos_a.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].heaLos_a.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.heaLos_a.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].heaLos_b.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.heaLos_b.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].heaLos_b.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.heaLos_b.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].senMasFlo.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.senMasFlo.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[1].senMasFlo.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.senMasFlo.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].res.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.res.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].res.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.res.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class bufSto.heatingCoil2.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].del.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.del.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].del.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.del.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].heaLos_a.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.heaLos_a.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].heaLos_a.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.heaLos_a.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].heaLos_b.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.heaLos_b.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].heaLos_b.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.heaLos_b.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].senMasFlo.port_a.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.senMasFlo.port_a.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25
Warning: Non-literal value.
In nominal attribute for bufSto.heatingCoil2.pipe[2].senMasFlo.port_b.h_outflow.
Ignoring nominal attribute.
In class Modelica.Media.Interfaces.Types.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921
Used in base-class bufSto.heatingCoil2.pipe.senMasFlo.port_b.FluidPort.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45
Warning: Incompatible sizes for variable and its definition equation;
TSupOld_design = TDemOld_design.+dTLoss_nominal.+dTTraOld_design
They have for dimension 1 the sizes 2 and 1.
Failure to expand could be due to unknown sizes, which is not an error
if the sizes are given when using the component.
Check of class aborted.
Warning: WARNINGS have been issued.
Error in model: BESMod.Systems.Hydraulical.Generation.Tests.SolarThermalAndHeatPumpSimple
Check of BESMod.Systems.Hydraulical.Generation.Tests.SolarThermalAndHeatPumpSimple:
Warning: Failed to evaluate and check the size declaration of systemParameters.QBui_flow_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: Failed to evaluate and check the size declaration of systemParameters.THydSup_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: Non-literal value.
In nominal attribute for generation.solThe.pressureDrop.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class generation.solThe.pressureDrop.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.nSet is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TConInMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TEvaOutMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowEvaMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowConMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Error: The following parameter doesn't have any value:
generation.dpDemOld_design
The model has the same number of unknowns and equations: 1376
The model could not be deduced to be symbolically well-posed.
The model has
1349+2*(generation.heatPump.innerCycle.PerformanceDataHPHeating.multiplex3_1.n1+ generation.heatPump.innerCycle.PerformanceDataHPHeating.multiplex3_1.n2+ generation.heatPump.innerCycle.PerformanceDataHPHeating.multiplex3_1.n3)+ generation.heatPump.con.vol.dynBal.nPorts+2*generation.heatPump.eva.vol.dynBal.nPorts +generation.pump.vol.dynBal.nPorts+generation.multiSum.nu+generation.eleHea.vol.dynBal.nPorts +generation.solThe.vol.dynBal.nPorts+generation.pumpSolThe.vol.dynBal.nPorts+ vol[1].dynBal.nPorts+vol[2].dynBal.nPorts
scalar unknowns and
1290+2*(generation.heatPump.innerCycle.PerformanceDataHPHeating.multiplex3_1.n1+ generation.heatPump.innerCycle.PerformanceDataHPHeating.multiplex3_1.n2+ generation.heatPump.innerCycle.PerformanceDataHPHeating.multiplex3_1.n3)+(if generation.bou_sinkAir.use_Xi_in then 2 else (if generation.bou_sinkAir.use_X_in then 1 else 3))+(if not generation.bou_sinkAir.use_p_in then 1 else 0)+(if not generation.bou_sinkAir.use_h_in then 1 else 0)+(if generation.bouEva.use_Xi_in then 2 else (if generation.bouEva.use_X_in then 1 else 3))+(if generation.bouPum.use_Xi_in then 1 else (if generation.bouPum.use_X_in then 0 else 1))+(if not generation.bouPum.use_p_in then 1 else 0)+(if not generation.bouPum.use_T_in then 1 else 0)+(if generation.bou.use_Xi_in then 1 else (if generation.bou.use_X_in then 0 else 1))+(if not generation.bou.use_p_in then 1 else 0)+2*generation.bou.nPorts+(if not generation.bou.use_T_in then 1 else 0)+(if weaDat.pAtmSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TDewPoiSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TDryBulSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TBlaSkySou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.relHumSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.opaSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.ceiHeiSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.totSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winSpeSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winDirSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HInfHorSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HDifHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HGloHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HGloHor_HDifHor then 2 else 1)+(if not generation.heatPump.con.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.heatPump.con.vol.dynBal.nPorts+(if not generation.heatPump.eva.vol.dynBal.use_mWat_flow then 1 else 0)+5* generation.heatPump.eva.vol.dynBal.nPorts+(if not generation.pump.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.pump.vol.dynBal.nPorts+(if not generation.eleHea.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.eleHea.vol.dynBal.nPorts+(if not generation.solThe.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.solThe.vol.dynBal.nPorts +(if not generation.pumpSolThe.vol.dynBal.use_mWat_flow then 1 else 0)+3* generation.pumpSolThe.vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts+(if not vol[2].dynBal.use_mWat_flow then 1 else 0)+3*vol[2].dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
1376
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Distribution.Tests.TestSimpleStorages
Check of BESMod.Systems.Hydraulical.Distribution.Tests.TestSimpleStorages:
Error: The following parameters don't have any value:
distribution.mDemOld_flow_design
distribution.mSupOld_flow_design
The model has the same number of unknowns and equations: 1591
The model could not be deduced to be symbolically well-posed.
The model has
1550+distribution.stoDHW.layer[1].dynBal.nPorts+distribution.stoDHW.layer[2].dynBal.nPorts +distribution.stoDHW.layer[3].dynBal.nPorts+distribution.stoDHW.layer[4].dynBal.nPorts +distribution.stoDHW.layer_HE[1].dynBal.nPorts+distribution.stoDHW.layer_HE[2].dynBal.nPorts +distribution.stoDHW.layer_HE[3].dynBal.nPorts+distribution.stoDHW.layer_HE[4].dynBal.nPorts +distribution.stoBuf.layer[1].dynBal.nPorts+distribution.stoBuf.layer[2].dynBal.nPorts +distribution.stoBuf.layer[3].dynBal.nPorts+distribution.stoBuf.layer[4].dynBal.nPorts +distribution.stoBuf.layer_HE[1].dynBal.nPorts+distribution.stoBuf.layer_HE[2].dynBal.nPorts +distribution.stoBuf.layer_HE[3].dynBal.nPorts+distribution.stoBuf.layer_HE[4].dynBal.nPorts +distribution.threeWayValveWithFlowReturn.threWayValFlow.vol.dynBal.nPorts+ fanTra[1].vol.dynBal.nPorts+fanDHW.vol.dynBal.nPorts+fanGen[1].vol.dynBal.nPorts
scalar unknowns and
1436+(if distribution.bouPumBuf.use_Xi_in then 1 else (if distribution.bouPumBuf.use_X_in then 0 else 1))+(if not distribution.bouPumBuf.use_p_in then 1 else 0)+(if not distribution.bouPumBuf.use_T_in then 1 else 0)+(if bouDHW.use_Xi_in then 1 else (if bouDHW.use_X_in then 0 else 1))+(if not bouDHW.use_p_in then 1 else 0)+(if not bouDHW.use_T_in then 1 else 0)+(if bouTra[1].use_Xi_in then 1 else (if bouTra[1].use_X_in then 0 else 1))+(if not bouTra[1].use_p_in then 1 else 0)+(if not bouTra[1].use_T_in then 1 else 0)+(if bouTra1[1].use_Xi_in then 1 else (if bouTra1[1].use_X_in then 0 else 1))+(if not bouTra1[1].use_p_in then 1 else 0)+(if not bouTra1[1].use_T_in then 1 else 0)+(if not fanTra[1].vol.dynBal.use_mWat_flow then 1 else 0)+3*fanTra[1].vol.dynBal.nPorts +(if not fanDHW.vol.dynBal.use_mWat_flow then 1 else 0)+3*fanDHW.vol.dynBal.nPorts +(if not fanGen[1].vol.dynBal.use_mWat_flow then 1 else 0)+3*fanGen[1].vol.dynBal.nPorts +(if not distribution.stoDHW.layer[1].dynBal.use_mWat_flow then 1 else 0)+3* distribution.stoDHW.layer[1].dynBal.nPorts+(if not distribution.stoDHW.layer[2].dynBal.use_mWat_flow then 1 else 0)+3*distribution.stoDHW.layer[2].dynBal.nPorts+(if not distribution.stoDHW.layer[3].dynBal.use_mWat_flow then 1 else 0)+3* distribution.stoDHW.layer[3].dynBal.nPorts+(if not distribution.stoDHW.layer[4].dynBal.use_mWat_flow then 1 else 0)+3*distribution.stoDHW.layer[4].dynBal.nPorts+(if not distribution.stoDHW.layer_HE[1].dynBal.use_mWat_flow then 1 else 0)+3* distribution.stoDHW.layer_HE[1].dynBal.nPorts+(if not distribution.stoDHW.layer_HE[2].dynBal.use_mWat_flow then 1 else 0)+3*distribution.stoDHW.layer_HE[2].dynBal.nPorts+(if not distribution.stoDHW.layer_HE[3].dynBal.use_mWat_flow then 1 else 0)+3* distribution.stoDHW.layer_HE[3].dynBal.nPorts+(if not distribution.stoDHW.layer_HE[4].dynBal.use_mWat_flow then 1 else 0)+3*distribution.stoDHW.layer_HE[4].dynBal.nPorts+(if not distribution.stoBuf.layer[1].dynBal.use_mWat_flow then 1 else 0)+3* distribution.stoBuf.layer[1].dynBal.nPorts+(if not distribution.stoBuf.layer[2].dynBal.use_mWat_flow then 1 else 0)+3*distribution.stoBuf.layer[2].dynBal.nPorts+(if not distribution.stoBuf.layer[3].dynBal.use_mWat_flow then 1 else 0)+3* distribution.stoBuf.layer[3].dynBal.nPorts+(if not distribution.stoBuf.layer[4].dynBal.use_mWat_flow then 1 else 0)+3*distribution.stoBuf.layer[4].dynBal.nPorts+(if not distribution.stoBuf.layer_HE[1].dynBal.use_mWat_flow then 1 else 0)+3* distribution.stoBuf.layer_HE[1].dynBal.nPorts+(if not distribution.stoBuf.layer_HE[2].dynBal.use_mWat_flow then 1 else 0)+3*distribution.stoBuf.layer_HE[2].dynBal.nPorts+(if not distribution.stoBuf.layer_HE[3].dynBal.use_mWat_flow then 1 else 0)+3* distribution.stoBuf.layer_HE[3].dynBal.nPorts+(if not distribution.stoBuf.layer_HE[4].dynBal.use_mWat_flow then 1 else 0)+3*distribution.stoBuf.layer_HE[4].dynBal.nPorts+(if not distribution.threeWayValveWithFlowReturn.threWayValFlow.vol.dynBal.use_mWat_flow then 1 else 0)+3*distribution.threeWayValveWithFlowReturn.threWayValFlow.vol.dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
1591
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Transfer.Tests.TestUnderfloorHeating
Check of BESMod.Systems.Hydraulical.Transfer.Tests.TestUnderfloorHeating:
Note:
Your model is using an outer "system" component but
an inner "system" component is not defined.
For simulation drag Modelica.Fluid.System into your model
to specify system properties.
Warning: For variable transfer.ufh[1].panelHeatingSegment[1].HeatConv.calcMethod
declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component transfer.ufh[1].panelHeatingSegment[1].HeatConv.
Type inconsistent definition equation:
transfer.ufh[1].panelHeatingSegment[1].HeatConv.calcMethod = transfer.ufh[1].panelHeatingSegment[1].calcMethod;
Warning: The types of the operands in (transfer.ufh[1].panelHeatingSegment[1].HeatConv.calcMethod) = ( transfer.ufh[1].panelHeatingSegment[1].calcMethod)
are Enumeration and Integer, but they must be compatible.
Variable transfer.ufh[1].panelHeatingSegment[1].calcMethod was declared in class BESMod.Systems.Hydraulical.Components.UFH.PanelHeatingSegment, /builds/EBC/EBC_all/github_ci/BESMod/BESMod/Systems/Hydraulical/Components/UFH/PanelHeatingSegment.mo at line 26, and used in component transfer.ufh[1].panelHeatingSegment[1].
Warning: For variable transfer.ufh[1].panelHeatingSegment[1].HeatConv.surfaceOrientation
declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component transfer.ufh[1].panelHeatingSegment[1].HeatConv.
Type inconsistent definition equation:
transfer.ufh[1].panelHeatingSegment[1].HeatConv.surfaceOrientation = (if transfer.ufh[1].panelHeatingSegment[1].isFloor then 2 else 1);
Warning: The types of the operands in (transfer.ufh[1].panelHeatingSegment[1].HeatConv.surfaceOrientation) = (( if transfer.ufh[1].panelHeatingSegment[1].isFloor then 2 else 1))
are Enumeration and Integer, but they must be compatible.
Warning: For variable transfer.ufh[1].panelHeatingSegment[2].HeatConv.calcMethod
declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component transfer.ufh[1].panelHeatingSegment[2].HeatConv.
Type inconsistent definition equation:
transfer.ufh[1].panelHeatingSegment[2].HeatConv.calcMethod = transfer.ufh[1].panelHeatingSegment[2].calcMethod;
Warning: The types of the operands in (transfer.ufh[1].panelHeatingSegment[2].HeatConv.calcMethod) = ( transfer.ufh[1].panelHeatingSegment[2].calcMethod)
are Enumeration and Integer, but they must be compatible.
Variable transfer.ufh[1].panelHeatingSegment[2].calcMethod was declared in class BESMod.Systems.Hydraulical.Components.UFH.PanelHeatingSegment, /builds/EBC/EBC_all/github_ci/BESMod/BESMod/Systems/Hydraulical/Components/UFH/PanelHeatingSegment.mo at line 26, and used in component transfer.ufh[1].panelHeatingSegment[2].
Warning: For variable transfer.ufh[1].panelHeatingSegment[2].HeatConv.surfaceOrientation
declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component transfer.ufh[1].panelHeatingSegment[2].HeatConv.
Type inconsistent definition equation:
transfer.ufh[1].panelHeatingSegment[2].HeatConv.surfaceOrientation = (if transfer.ufh[1].panelHeatingSegment[2].isFloor then 2 else 1);
Warning: The types of the operands in (transfer.ufh[1].panelHeatingSegment[2].HeatConv.surfaceOrientation) = (( if transfer.ufh[1].panelHeatingSegment[2].isFloor then 2 else 1))
are Enumeration and Integer, but they must be compatible.
Warning: For variable transfer.ufh[1].panelHeatingSegment[3].HeatConv.calcMethod
declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component transfer.ufh[1].panelHeatingSegment[3].HeatConv.
Type inconsistent definition equation:
transfer.ufh[1].panelHeatingSegment[3].HeatConv.calcMethod = transfer.ufh[1].panelHeatingSegment[3].calcMethod;
Warning: The types of the operands in (transfer.ufh[1].panelHeatingSegment[3].HeatConv.calcMethod) = ( transfer.ufh[1].panelHeatingSegment[3].calcMethod)
are Enumeration and Integer, but they must be compatible.
Variable transfer.ufh[1].panelHeatingSegment[3].calcMethod was declared in class BESMod.Systems.Hydraulical.Components.UFH.PanelHeatingSegment, /builds/EBC/EBC_all/github_ci/BESMod/BESMod/Systems/Hydraulical/Components/UFH/PanelHeatingSegment.mo at line 26, and used in component transfer.ufh[1].panelHeatingSegment[3].
Warning: For variable transfer.ufh[1].panelHeatingSegment[3].HeatConv.surfaceOrientation
declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component transfer.ufh[1].panelHeatingSegment[3].HeatConv.
Type inconsistent definition equation:
transfer.ufh[1].panelHeatingSegment[3].HeatConv.surfaceOrientation = (if transfer.ufh[1].panelHeatingSegment[3].isFloor then 2 else 1);
Warning: The types of the operands in (transfer.ufh[1].panelHeatingSegment[3].HeatConv.surfaceOrientation) = (( if transfer.ufh[1].panelHeatingSegment[3].isFloor then 2 else 1))
are Enumeration and Integer, but they must be compatible.
Warning: For variable transfer.ufh[1].panelHeatingSegment[4].HeatConv.calcMethod
declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component transfer.ufh[1].panelHeatingSegment[4].HeatConv.
Type inconsistent definition equation:
transfer.ufh[1].panelHeatingSegment[4].HeatConv.calcMethod = transfer.ufh[1].panelHeatingSegment[4].calcMethod;
Warning: The types of the operands in (transfer.ufh[1].panelHeatingSegment[4].HeatConv.calcMethod) = ( transfer.ufh[1].panelHeatingSegment[4].calcMethod)
are Enumeration and Integer, but they must be compatible.
Variable transfer.ufh[1].panelHeatingSegment[4].calcMethod was declared in class BESMod.Systems.Hydraulical.Components.UFH.PanelHeatingSegment, /builds/EBC/EBC_all/github_ci/BESMod/BESMod/Systems/Hydraulical/Components/UFH/PanelHeatingSegment.mo at line 26, and used in component transfer.ufh[1].panelHeatingSegment[4].
Warning: For variable transfer.ufh[1].panelHeatingSegment[4].HeatConv.surfaceOrientation
declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component transfer.ufh[1].panelHeatingSegment[4].HeatConv.
Type inconsistent definition equation:
transfer.ufh[1].panelHeatingSegment[4].HeatConv.surfaceOrientation = (if transfer.ufh[1].panelHeatingSegment[4].isFloor then 2 else 1);
Warning: The types of the operands in (transfer.ufh[1].panelHeatingSegment[4].HeatConv.surfaceOrientation) = (( if transfer.ufh[1].panelHeatingSegment[4].isFloor then 2 else 1))
are Enumeration and Integer, but they must be compatible.
Warning: For variable transfer.ufh[1].panelHeatingSegment[5].HeatConv.calcMethod
declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component transfer.ufh[1].panelHeatingSegment[5].HeatConv.
Type inconsistent definition equation:
transfer.ufh[1].panelHeatingSegment[5].HeatConv.calcMethod = transfer.ufh[1].panelHeatingSegment[5].calcMethod;
Warning: The types of the operands in (transfer.ufh[1].panelHeatingSegment[5].HeatConv.calcMethod) = ( transfer.ufh[1].panelHeatingSegment[5].calcMethod)
are Enumeration and Integer, but they must be compatible.
Variable transfer.ufh[1].panelHeatingSegment[5].calcMethod was declared in class BESMod.Systems.Hydraulical.Components.UFH.PanelHeatingSegment, /builds/EBC/EBC_all/github_ci/BESMod/BESMod/Systems/Hydraulical/Components/UFH/PanelHeatingSegment.mo at line 26, and used in component transfer.ufh[1].panelHeatingSegment[5].
Warning: For variable transfer.ufh[1].panelHeatingSegment[5].HeatConv.surfaceOrientation
declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component transfer.ufh[1].panelHeatingSegment[5].HeatConv.
Type inconsistent definition equation:
transfer.ufh[1].panelHeatingSegment[5].HeatConv.surfaceOrientation = (if transfer.ufh[1].panelHeatingSegment[5].isFloor then 2 else 1);
Warning: The types of the operands in (transfer.ufh[1].panelHeatingSegment[5].HeatConv.surfaceOrientation) = (( if transfer.ufh[1].panelHeatingSegment[5].isFloor then 2 else 1))
are Enumeration and Integer, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon)
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon
are Integer and Enumeration, but they must be compatible.
Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017
are Integer and Enumeration, but they must be compatible.
Error: The following parameter doesn't have any value:
transfer.dpSupOld_design
Warning: The following parameters don't have any value, only a start value:
transfer.TTraOld_design(start = {288.15})
The model has the same number of unknowns and equations: 1024
The model could not be deduced to be symbolically well-posed.
The model has
869+15*(transfer.ufh[1].panelHeatingSegment[1].vol.nPorts+transfer.ufh[1].panelHeatingSegment[2].vol.nPorts +transfer.ufh[1].panelHeatingSegment[3].vol.nPorts+transfer.ufh[1].panelHeatingSegment[4].vol.nPorts +transfer.ufh[1].panelHeatingSegment[5].vol.nPorts)+transfer.pumpFix_m_flow[1].vol.dynBal.nPorts +vol[1].dynBal.nPorts
scalar unknowns and
829+(if not transfer.ufh[1].panelHeatingSegment[1].vol.use_portsData then 4* transfer.ufh[1].panelHeatingSegment[1].vol.nPorts else 0)+13*transfer.ufh[1].panelHeatingSegment[1].vol.nPorts +(if not transfer.ufh[1].panelHeatingSegment[1].twoStar_RadEx.use_A_in then 1 else 0)+(if not transfer.ufh[1].panelHeatingSegment[2].vol.use_portsData then 4*transfer.ufh[1].panelHeatingSegment[2].vol.nPorts else 0)+13* transfer.ufh[1].panelHeatingSegment[2].vol.nPorts+(if not transfer.ufh[1].panelHeatingSegment[2].twoStar_RadEx.use_A_in then 1 else 0)+(if not transfer.ufh[1].panelHeatingSegment[3].vol.use_portsData then 4*transfer.ufh[1].panelHeatingSegment[3].vol.nPorts else 0)+13* transfer.ufh[1].panelHeatingSegment[3].vol.nPorts+(if not transfer.ufh[1].panelHeatingSegment[3].twoStar_RadEx.use_A_in then 1 else 0)+(if not transfer.ufh[1].panelHeatingSegment[4].vol.use_portsData then 4*transfer.ufh[1].panelHeatingSegment[4].vol.nPorts else 0)+13* transfer.ufh[1].panelHeatingSegment[4].vol.nPorts+(if not transfer.ufh[1].panelHeatingSegment[4].twoStar_RadEx.use_A_in then 1 else 0)+(if not transfer.ufh[1].panelHeatingSegment[5].vol.use_portsData then 4*transfer.ufh[1].panelHeatingSegment[5].vol.nPorts else 0)+13* transfer.ufh[1].panelHeatingSegment[5].vol.nPorts+(if not transfer.ufh[1].panelHeatingSegment[5].twoStar_RadEx.use_A_in then 1 else 0)+(if bou1[1].use_Xi_in then 1 else (if bou1[1].use_X_in then 0 else 1))+(if not bou1[1].use_p_in then 1 else 0)+(if not bou1[1].use_T_in then 1 else 0)+(if not transfer.pumpFix_m_flow[1].vol.dynBal.use_mWat_flow then 1 else 0)+3*transfer.pumpFix_m_flow[1].vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
1024
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Distribution.Tests.TestBoilerWithDHW
Check of BESMod.Systems.Hydraulical.Distribution.Tests.TestBoilerWithDHW:
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[1].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[2].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[3].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil1.pipe[4].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil1.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.boi.pressureDrop.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.boi.pressureDrop.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil2.pipe[1].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil2.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil2.pipe[2].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil2.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil2.pipe[3].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil2.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: Non-literal value.
In nominal attribute for distribution.stoDHW.heatingCoil2.pipe[4].res.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class distribution.stoDHW.heatingCoil2.pipe.res.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Error: The following parameters don't have any value:
distribution.mDemOld_flow_design
distribution.mSupOld_flow_design
The model has the same number of unknowns and equations: 4141
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Generation.Tests.HeatPumpAndGasBoilerSeries
Check of BESMod.Systems.Hydraulical.Generation.Tests.HeatPumpAndGasBoilerSeries:
Warning: Failed to evaluate and check the size declaration of systemParameters.QBui_flow_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: Failed to evaluate and check the size declaration of systemParameters.THydSup_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: Non-literal value.
In nominal attribute for generation.boi.pressureDrop.dp.
Ignoring nominal attribute.
In class Modelica.Units.SI.
Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237
Used in base-class generation.boi.pressureDrop.PartialTwoPortInterface.
Near file: /builds/EBC/EBC_all/github_ci/BESMod/installed_dependencies/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowEvaMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowConMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.nSet is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TConInMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TEvaOutMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Error: The following parameter doesn't have any value:
generation.dpDemOld_design
The model has the same number of unknowns and equations: 1086
The model could not be deduced to be symbolically well-posed.
The model has
1072+generation.heatPump.con.vol.dynBal.nPorts+2*generation.heatPump.eva.vol.dynBal.nPorts +generation.pump.vol.dynBal.nPorts+generation.multiSum.nu+generation.boi.vol.dynBal.nPorts +vol[1].dynBal.nPorts
scalar unknowns and
1032+(if generation.bou_sinkAir.use_Xi_in then 2 else (if generation.bou_sinkAir.use_X_in then 1 else 3))+(if not generation.bou_sinkAir.use_p_in then 1 else 0)+(if not generation.bou_sinkAir.use_h_in then 1 else 0)+(if generation.bouEva.use_Xi_in then 2 else (if generation.bouEva.use_X_in then 1 else 3))+(if generation.bouPum.use_Xi_in then 1 else (if generation.bouPum.use_X_in then 0 else 1))+(if not generation.bouPum.use_p_in then 1 else 0)+(if not generation.bouPum.use_T_in then 1 else 0)+(if weaDat.pAtmSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDewPoiSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDryBulSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TBlaSkySou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.relHumSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.opaSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.ceiHeiSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.totSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winSpeSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winDirSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HInfHorSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HDifHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HGloHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HGloHor_HDifHor then 2 else 1)+(if not generation.heatPump.con.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.heatPump.con.vol.dynBal.nPorts+(if not generation.heatPump.eva.vol.dynBal.use_mWat_flow then 1 else 0)+5* generation.heatPump.eva.vol.dynBal.nPorts+(if not generation.pump.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.pump.vol.dynBal.nPorts+(if not generation.boi.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.boi.vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
1086
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Generation.Tests.HeatPumpAndElectricHeater
Check of BESMod.Systems.Hydraulical.Generation.Tests.HeatPumpAndElectricHeater:
Warning: Failed to evaluate and check the size declaration of systemParameters.QBui_flow_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: Failed to evaluate and check the size declaration of systemParameters.THydSup_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.nSet is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TConInMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TEvaOutMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowEvaMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowConMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Error: The following parameter doesn't have any value:
generation.dpDemOld_design
The model has the same number of unknowns and equations: 1059
The model could not be deduced to be symbolically well-posed.
The model has
1044+generation.heatPump.con.vol.dynBal.nPorts+2*generation.heatPump.eva.vol.dynBal.nPorts +generation.pump.vol.dynBal.nPorts+generation.multiSum.nu+generation.eleHea.vol.dynBal.nPorts +vol[1].dynBal.nPorts
scalar unknowns and
1005+(if generation.bou_sinkAir.use_Xi_in then 2 else (if generation.bou_sinkAir.use_X_in then 1 else 3))+(if not generation.bou_sinkAir.use_p_in then 1 else 0)+(if not generation.bou_sinkAir.use_h_in then 1 else 0)+(if generation.bouEva.use_Xi_in then 2 else (if generation.bouEva.use_X_in then 1 else 3))+(if generation.bouPum.use_Xi_in then 1 else (if generation.bouPum.use_X_in then 0 else 1))+(if not generation.bouPum.use_p_in then 1 else 0)+(if not generation.bouPum.use_T_in then 1 else 0)+(if weaDat.pAtmSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDewPoiSou == IBPSA.BoundaryConditions.Types.DataSource.Parameter then 1 else 0)+(if weaDat.TDryBulSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TBlaSkySou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.relHumSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.opaSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.ceiHeiSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.totSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winSpeSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winDirSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HInfHorSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HDifHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HGloHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HGloHor_HDifHor then 2 else 1)+(if not generation.heatPump.con.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.heatPump.con.vol.dynBal.nPorts+(if not generation.heatPump.eva.vol.dynBal.use_mWat_flow then 1 else 0)+5* generation.heatPump.eva.vol.dynBal.nPorts+(if not generation.pump.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.pump.vol.dynBal.nPorts+(if not generation.eleHea.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.eleHea.vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
1059
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Generation.Tests.SolarThermalAndHeatPumpDetailed
Check of BESMod.Systems.Hydraulical.Generation.Tests.SolarThermalAndHeatPumpDetailed:
Warning: Failed to evaluate and check the size declaration of systemParameters.QBui_flow_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: Failed to evaluate and check the size declaration of systemParameters.THydSup_nominal.
The definition equation or start value requires a certain size.
Warning: For dimension 1 the size declaration is systemParameters.nZones, and the required size is 1.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.nSet is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TConInMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.TEvaOutMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowEvaMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Warning: The variable generation.heatPump.innerCycle.PerformanceDataHPCooling.sigBus.m_flowConMea is part of an expandable connector, and was only used outside of connect. That is not legal since we cannot determine its causality.
Error: The following parameter doesn't have any value:
generation.dpDemOld_design
The model has the same number of unknowns and equations: 1844
The model could not be deduced to be symbolically well-posed.
The model has
1785+6*generation.solCol.nSeg+generation.heatPump.con.vol.dynBal.nPorts+2* generation.heatPump.eva.vol.dynBal.nPorts+generation.pump.vol.dynBal.nPorts+ generation.multiSum.nu+generation.eleHea.vol.dynBal.nPorts+generation.solCol.vol[1].dynBal.nPorts +generation.solCol.vol[2].dynBal.nPorts+generation.solCol.vol[3].dynBal.nPorts +generation.solCol.vol[4].dynBal.nPorts+generation.solCol.vol[5].dynBal.nPorts +generation.pumpSolThe.vol.dynBal.nPorts+vol[1].dynBal.nPorts+vol[2].dynBal.nPorts
scalar unknowns and
1714+(if generation.bou_sinkAir.use_Xi_in then 2 else (if generation.bou_sinkAir.use_X_in then 1 else 3))+(if not generation.bou_sinkAir.use_p_in then 1 else 0)+(if not generation.bou_sinkAir.use_h_in then 1 else 0)+(if generation.bouEva.use_Xi_in then 2 else (if generation.bouEva.use_X_in then 1 else 3))+(if generation.bouPum.use_Xi_in then 1 else (if generation.bouPum.use_X_in then 0 else 1))+(if not generation.bouPum.use_p_in then 1 else 0)+(if not generation.bouPum.use_T_in then 1 else 0)+2*(if not generation.solCol.use_shaCoe_in then 1 else 0)+4*generation.solCol.nSeg+(if generation.bou.use_Xi_in then 1 else (if generation.bou.use_X_in then 0 else 1))+(if not generation.bou.use_p_in then 1 else 0)+2*generation.bou.nPorts+(if not generation.bou.use_T_in then 1 else 0)+(if weaDat.pAtmSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TDewPoiSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TDryBulSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.TBlaSkySou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.relHumSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.opaSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.ceiHeiSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.totSkyCovSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winSpeSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.winDirSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HInfHorSou == IBPSA.BoundaryConditions.Types.DataSource. Parameter then 1 else 0)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HDifHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HDirNor_HGloHor then 2 else 1)+(if weaDat.HSou == IBPSA.BoundaryConditions.Types.RadiationDataSource. Input_HGloHor_HDifHor then 2 else 1)+(if not generation.heatPump.con.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.heatPump.con.vol.dynBal.nPorts+(if not generation.heatPump.eva.vol.dynBal.use_mWat_flow then 1 else 0)+5* generation.heatPump.eva.vol.dynBal.nPorts+(if not generation.pump.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.pump.vol.dynBal.nPorts+(if not generation.eleHea.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.eleHea.vol.dynBal.nPorts+(if not generation.solCol.vol[1].dynBal.use_mWat_flow then 1 else 0)+3* generation.solCol.vol[1].dynBal.nPorts+(if not generation.solCol.vol[2].dynBal.use_mWat_flow then 1 else 0)+3*generation.solCol.vol[2].dynBal.nPorts+(if not generation.solCol.vol[3].dynBal.use_mWat_flow then 1 else 0)+3* generation.solCol.vol[3].dynBal.nPorts+(if not generation.solCol.vol[4].dynBal.use_mWat_flow then 1 else 0)+3*generation.solCol.vol[4].dynBal.nPorts+(if not generation.solCol.vol[5].dynBal.use_mWat_flow then 1 else 0)+3* generation.solCol.vol[5].dynBal.nPorts+(if not generation.pumpSolThe.vol.dynBal.use_mWat_flow then 1 else 0)+3*generation.pumpSolThe.vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts+(if not vol[2].dynBal.use_mWat_flow then 1 else 0)+3*vol[2].dynBal.nPorts
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
1844
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.
Error in model: BESMod.Systems.Hydraulical.Transfer.Tests.TestIdealValveRadiatorSystem
Check of BESMod.Systems.Hydraulical.Transfer.Tests.TestIdealValveRadiatorSystem:
Error: The following parameter doesn't have any value:
transfer.dpSupOld_design
Warning: The following parameters don't have any value, only a start value:
transfer.TTraOld_design(start = {288.15})
The model has the same number of unknowns and equations: 572
The model could not be deduced to be symbolically well-posed.
The model has
537+2*transfer.parRad.nEle+transfer.rad[1].sumCon.nin+transfer.rad[1].sumRad.nin +transfer.rad[1].vol[1].dynBal.nPorts+transfer.rad[1].vol[2].dynBal.nPorts+ transfer.rad[1].vol[3].dynBal.nPorts+transfer.rad[1].vol[4].dynBal.nPorts+ transfer.rad[1].vol[5].dynBal.nPorts+transfer.pumFixMFlo[1].vol.dynBal.nPorts+ vol[1].dynBal.nPorts
scalar unknowns and
507+(if bou1[1].use_Xi_in then 1 else (if bou1[1].use_X_in then 0 else 1))+(if not bou1[1].use_p_in then 1 else 0)+(if not bou1[1].use_T_in then 1 else 0)+ (if not transfer.pumFixMFlo[1].vol.dynBal.use_mWat_flow then 1 else 0)+3* transfer.pumFixMFlo[1].vol.dynBal.nPorts+(if not vol[1].dynBal.use_mWat_flow then 1 else 0)+3*vol[1].dynBal.nPorts+(if not transfer.rad[1].vol[1].dynBal.use_mWat_flow then 1 else 0)+3*transfer.rad[1].vol[1].dynBal.nPorts+(if not transfer.rad[1].vol[2].dynBal.use_mWat_flow then 1 else 0)+3*transfer.rad[1].vol[2].dynBal.nPorts +(if not transfer.rad[1].vol[3].dynBal.use_mWat_flow then 1 else 0)+3* transfer.rad[1].vol[3].dynBal.nPorts+(if not transfer.rad[1].vol[4].dynBal.use_mWat_flow then 1 else 0)+3*transfer.rad[1].vol[4].dynBal.nPorts+(if not transfer.rad[1].vol[5].dynBal.use_mWat_flow then 1 else 0)+3*transfer.rad[1].vol[5].dynBal.nPorts +2*transfer.parRad.nEle
scalar equations.
However, exploiting the given numerical settings of parameters gives the same number of unknowns and equations:
572
Warning: WARNINGS have been issued.
Error: ERRORS have been issued.