# created April 2023
# by TEASER4 Development Team
from teaser.logic.buildingobjects.buildingphysics.interzonalwall \
import InterzonalWall
[docs]
class InterzonalFloor(InterzonalWall):
"""InterzonalFloor (InterzonalWall)
This class represents an interzonal floor and is a child of InterzonalWall()
Note that interzonal elements have to be created twice for each zone they
connect and are not semantically connected afterwards. For an
InterzonalFloor of one zone, an InterzonalCeiling has to be created for the
zone on the other side.
Parameters
----------
parent : ThermalZone()
The parent class of this object, the ThermalZone the BE belongs to.
Allows for better control of hierarchical structures. If not None it
adds this InterzonalFloor to ThermalZone.interzonal_floors.
Default is None.
Attributes
----------
internal_id : float
Random id for the distinction between different elements.
name : str
Individual name
construction_data : str
Type of construction (e.g. "heavy" or "light"). Needed for
distinction between different constructions types in the same
building age period.
year_of_retrofit : int
Year of last retrofit
year_of_construction : int
Year of first construction
building_age_group : list
Determines the building age period that this building
element belongs to [begin, end], e.g. [1984, 1994]
area : float [m2]
Area of building element
tilt : float [degree]
Tilt against horizontal, default is 0.0
orientation : float [degree]
Azimuth direction of building element (0 : north, 90: east, 180: south,
270: west), default is -2, for horizontal floor
inner_convection : float [W/(m2*K)]
Constant heat transfer coefficient of convection inner side (facing
the zone), default is 1.7
inner_radiation : float [W/(m2*K)]
Constant heat transfer coefficient of radiation inner side (facing
the zone), default is 5.0
outer_convection : float [W/(m2*K)]
Constant heat transfer coefficient of convection outer side (facing
the ambient or adjacent zone). Default 0.0 - if unchanged, 1.7 when
adding an outside
outer_radiation : float [W/(m2*K)]
Constant heat transfer coefficient of radiation outer side (facing
the ambient or adjacent zone). Default 0.0 - if unchanged, 5.0 when
adding an outside
layer : list
List of all layers of a building element (to be filled with Layer
objects). Use element.layer = None to delete all layers of the building
element
other_side : ThermalZone()
the thermal zone on the upper side of the interzonal floor
interzonal_type_material : str
one of (None (default), 'inner', 'outer_ordered', 'outer_reversed')
describes as which kind of element the element is treated when loading
type elements. Caution: Make sure that the complimentary element of
the other zone is also changed accordingly if this is adapted manually
None: treatment based on project.method_interzonal_export_enrichment
'inner': InterzonalWall treated as InnerWall,
InterzonalFloor treated as Floor,
InterzonalCeiling treated as Ceiling
'outer_ordered': InterzonalWall treated as Wall,
InterzonalFloor treated as GroundFloor,
InterzonalCeiling treated as Rooftop
'outer_reversed': like 'outer_ordered', but with reversed layers,
resulting in the reversed sequence of layers as
for the complimentary element declared as
'outer_ordered'
interzonal_type_export : str
one of (None (default), 'inner', 'outer_ordered', 'outer_reversed')
describes as which kind of element the element is treated when exporting
to Modelica. Caution: Make sure that the complimentary element of
the other zone is also changed accordingly if this is adapted manually
'inner': element will be lumped with InnerWall. No heat flow to the
zone on the other side will be modelled.
'outer_ordered': element will be lumped with OuterWall (OneElement
to FourElement export) or treated as border to an
adjacent zone (FiveElement export). Borders to the
same adjacent zone will be lumped.
'outer_reversed': like 'outer_ordered', but the lumping follows
VDI 6007-1 in reversed order, resulting in the
reversed order of resistances and capacitors as
for the complimentary element declared as
'outer_ordered'
Calculated Attributes
r1 : float [K/W]
equivalent resistance R1 of the analogous model given in VDI 6007
r2 : float [K/W]
equivalent resistance R2 of the analogous model given in VDI 6007
r3 : float [K/W]
equivalent resistance R3 of the analogous model given in VDI 6007
c1 : float [J/K]
equivalent capacity C1 of the analogous model given in VDI 6007
c2 : float [J/K]
equivalent capacity C2 of the analogous model given in VDI 6007
c1_korr : float [J/K]
corrected capacity C1,korr for building elements in the case of
asymmetrical thermal load given in VDI 6007
ua_value : float [W/K]
UA-Value of building element (Area times U-Value)
r_inner_conv : float [K/W]
Convective resistance of building element on inner side (facing the
zone)
r_inner_rad : float [K/W]
Radiative resistance of building element on inner side (facing the
zone)
r_inner_conv : float [K/W]
Combined convective and radiative resistance of building element on
inner side (facing the zone)
r_outer_conv : float [K/W]
Convective resistance of building element on outer side (facing
the ambient or adjacent zone). Currently for all InnerWalls and
GroundFloors this value is set to 0.0
r_outer_rad : float [K/W]
Radiative resistance of building element on outer side (facing
the ambient or adjacent zone). Currently for all InnerWalls and
GroundFloors this value is set to 0.0
r_outer_comb : float [K/W]
Combined convective and radiative resistance of building element on
outer side (facing the ambient or adjacent zone). Currently for all
InnerWalls and GroundFloors this value is set to 0.0
wf_out : float
Weightfactor of building element ua_value/ua_value_zone
"""
def __init__(self, parent=None, other_side=None):
"""
"""
super(InterzonalFloor, self).__init__(parent, other_side)
self._tilt = 0.0
self._orientation = -2.0
[docs]
def retrofit_wall(self,
year_of_retrofit,
material=None,
add_at_position=None):
"""Retrofits wall to German refurbishment standards.
This function adds an additional layer of insulation and sets the
thickness of the layer according to the retrofit standard in the
year of refurbishment. Refurbishment year must be newer then 1977
Note: To Calculate thickness and U-Value, the standard TEASER
coefficients for outer and inner heat transfer are used.
The used Standards are namely the Waermeschutzverordnung (WSVO) and
Energieeinsparverordnung (EnEv)
Parameters
----------
material : string
Type of material, that is used for insulation
year_of_retrofit : int
Year of the retrofit of the wall/building
add_at_position : int
position at which to insert the insulation layer.
0 inside, None (default) or -1 outside/other side
"""
if self.interzonal_type_material == 'inner':
return
elif add_at_position is None:
if self.interzonal_type_material == 'outer_reversed':
add_at_position = 0
elif self.interzonal_type_material == 'outer_ordered':
add_at_position = -1
material, year_of_retrofit, ins_layer = self.initialize_retrofit(
material, year_of_retrofit, add_at_position
)
calc_u = None
if 1977 <= year_of_retrofit <= 1981:
calc_u = 0.8
elif 1982 <= year_of_retrofit <= 1994:
calc_u = 0.7
elif 1995 <= year_of_retrofit <= 2001:
calc_u = 0.5
elif 2002 <= year_of_retrofit <= 2008:
calc_u = 0.4
elif 2009 <= year_of_retrofit <= 2013:
calc_u = 0.3
elif year_of_retrofit >= 2014:
calc_u = 0.3
self.set_insulation(material, calc_u, year_of_retrofit,
ins_layer_index=ins_layer)